Load-cell Automatic Vickers Hardness Tester

Load-cell Automatic Vickers Hardness Tester FLV-AR

An official distributor of Future-Tech in Vietnam

LOAD-CELL AUTOMATIC VICKERS HARDNESS TESTER FLV-AR Series

Load-cell Automatic Vickers Hardness Tester is a fully-automatic microhardness

Features of Load-cell Automatic Vickers Hardness Tester

FLV-AS series is a fully automatic Vickers hardness tester series manufactured by Future-Tech – Japan

Outstanding features of the machine

  • Load-cell type loading mechanism.
  • Load applying mechanism by elevating the head.
  • High-resolution camera.
  • Sample surface inclination / slope correction function.
  • Sample image saving function.
  • Large motorized XY stage.
  • Various measuring patterns.
  • A function that traces the edge of a sample as a standard feature.
  • Professional software of image processing.
  • Various output data formats and statistical processing.

FT-ZERO Software

Distance & Angle Measurement Function

Only click between two points can measure the distance and click three points can measure the angle easily.

Edge tracing of image function

The original position set is very simple by this function to recognize a shape of sample automatically.

Pattern Setting

Vickers Hardness Tester - Pattern Setting

Easily set the complicated pattern by clicking a graph. Test load and measurement lens can set it at a Line of each.

Report Graph Chart

Vickers Hardness Tester - Graph Charge

Measurement data can save it in CSV form and transfer to an original report.

Technical Information of Load-cell Automatic Vickers Hardness Tester

General specification of Load-cell Automatic Vickers Hardness Tester

FOCUSING METHODS

Automatic Operation (by integrated Auto-Reading Software) / Manual Operation (by motorized Positioning System)

TURRET ROTATION

Automatic-Motorized (by integrated Auto-Reading Software)

MEASUREMENT OF INDENTATION

Automatic Reading / Manual Reading (by integrated Auto-Reading Software)

LOAD APPLYING SPEED

Initial Descending Speed (to 0.15 mm level on specimen surface): Approx. 180 μm/s Effective Loading Speed: Approx. 30 μm/s for under 1kgf Test Load and Approx. 80 μm/s for over 1kgf Test Load

DWELL TIME

5~99sec

INDENTER

For Vickers Test (HV): 1pc (For Knoop Test (HK) and Brinell Test (HBW): Tungsten Ball φ1mm, φ2.5mm (OPTION))

OBJECTIVE LENS

Infinity Corrected Long Working Distance (LWD) Lens: 2pcs X10 & X50

Infinity Corrected LWD Lenses / Max. 5pcs : X1.25, X2.5, X5, X20, X40, X100 (OPTION)

Camera

Automatic measurement by Built-in Type 1.3Mpixel (Made in Germany)

System Control

  • Software

FT-ZERO (Windows 10 / 64bit) / Display Size 23”

  • Output signal

USB (RS232C Converter: built-in)

  • Dimensions

FLV-10AR:
Manual 110 x 110 mm

FLV-10ARS-F:
Auto 150 x 150 mm

  • X-Y Stay Movement

FLV-10AR:
Manual (X)50 x (Y)50mm

FLV-10ARS-F:
Auto (X)180 x (Y)110mm
with joystick controller

ACCURACY

For Vickers Test: Conforming to JIS B-7725, JIS B-7734, ASTM E-384 and ISO/ DIN6507-2

SAFETY DEVICE

Protection Cover on Turret for Indenter & Each Objective Lens

SUPPLY

1P AC100~115V / AC240V (50/60Hz): Selectable by SW

Load-cell Automatic Vickers Hardness Tester FLV-10AR and FLV-10ARS-F

Test Load – Vickers

HV 0.01   0.02   0.025   0.05   0.1   0.2   0.3   0.5    1   2   2.5   3   4   5   10 kgf

Test Load – Knoop

HK 0.01   0.02   0.025   0.05   0.1   0.2   0.3   0.5   1   2 kgf

Test Load – Brinell

HBW 1/1   1/2.5   1/5   1/10   1/30   2.5/6.25 mm/kgf

Optional Loading Setting

Possible to set max 64 kinds of test load in a range of 0.01~10kgf by min 0.01kgf.

LOADING SYSTEM

0.01 ~ 10kgf Test load: Automatic Direct Loading System with Load-cell closed-loop feedback

LOAD-CELL TYPE

0.01 ~ 10kgf: by Double Load-cell (Apply Test Load by 10gf)

MAX. HEIGHT OF SPECIMEN

FLV-10AR:
110mm From Manual Stage Top

FLV-10ARS-F:
110mm From Auto Stage Top

MAX. DEPTH OF SPECIMEN

180mm

LIGHT SOURCE

  • Bulb

LED Illumination

  • Filter

Manual Adapting / Removing

DIMENSIONS

H720 × W415 × D650 mm

WEIGHT POWER

Approx 90kg

Load-cell Automatic Vickers Hardness Tester FLV-50AR and FLV-50ARS-F

Test Load – Vickers

HV 0.01   0.1   0.2   0.25   0.3   0.5    1   2   2.5   3   4   5   10   20   30   50 kgf

Test Load – Knoop

HK 0.05   0.1   0.2   0.3   0.5   1   2 kgf

Test Load – Brinell

HBW 1/1   1/2.5   1/5   1/10   1/30   2.5/6.25   2.5/15.6   2.5/31.25 mm/kgf

Optional Loading Setting

Possible to set max 64 kinds of test load in a range of 0.05~50kgf by min 0.01kgf.

LOADING SYSTEM

0.05~50kgf Test Load: Automatic Direct Loading System with Load-Cell closed-loop feedback.

LOAD-CELL TYPE

0.05~50kgf: by Double Load Cell (Apply Test Load by 10gf)

MAX. HEIGHT OF SPECIMEN

FLV-50AR:
210mm From Manual Stage Top

FLV-50ARS-F:
210mm From Auto Stage Top

MAX. DEPTH OF SPECIMEN

180mm

LIGHT SOURCE

  • Bulb

LED Illumination

  • Filter

Manual Adapting / Removing

DIMENSIONS

H820 × W415 × D650 mm

WEIGHT POWER

Approx 95kg